Rapid Giardia Ag Test Kit

Product Name Rapid Giardia Ag Test Kit
Principle Immunochromatographic assay
Specimen Feces
Specification 10T/kit
Format Cassette
Assay Time 5-10 mins
Shelf Life 24 months
OEM Available

Products details

INTENDED USE

Rapid Giadia Ag Test kit is a sandwich lateral flow immunochromatographic assay for the qualitative detection of Giardia in dog’s or cat’s feces.

PRINCIPLE

Giardia Ag Test is based on sandwich lateral flow immunochromatographic assay. The test device has a testing window. The testing window has an invisible T (test) zone and C (control) zone. When sample is applied into the sample hole on the device, the liquid will laterally flow on the surface of the test strip. If there is enough Giardia antigen in the sample, a visible T band will appear. The C band should always appear after a sample is applied, indicating a valid result. By this means, the device can accurately indicate the presence of Giardia antigen in the sample.

KIT COMPONENT

-Test device, with disposable droppers

-Assay buffer

-Cotton swabs

-Products Manual

STORAGE & SHELF LIFE

Store at 2-30°C, out of sun light and moisture.

Shelf Life: 24 months

TEST PROCEDURE

1. Collect dog’s fresh feces with the cotton swab. Make the swab wet sufficiently. Do not use sticky or a lump of feces.

2. Insert the wet swab into the provided assay buffer tubes.  Agitate it at least 10 times to get efficient sample extraction. If the fecal particles are large, let it stand for 1-2 minutes to precipitate.

3. Take out the test device from the foil pouch and place it horizontally.

4. Gradually drip 4 drops of sample extraction into the sample hole with disposable droppers.

5. Interpret the result in 5-10 minutes. Result after 10 minutes is considered as invalid.

image.png

INTERPRETATION OF RESULTS

Positive: Two lines appear, no matter T line is clear or vague.

Negative: Only C line appears.

Invalid: No line appears or only T line appears.

image.png

PRECAUTIONS

1. The test must be used within 1 hour after opening the foil pouch.

2. Adding too much feces samples will cause false positive and overdosing assay buffer can also lead to incorrect results.

3. Extract samples should be tested immediately.

4. Do not use the expired test or the test with damaged foil pouch.

5. Do not reuse the test kit and do not mix components from different lot numbers.

LIMITATION

SHENUNGTEX Rapid Giadia Ag Test Kit is for in vitro veterinary diagnosis use only. All results should be considered with other clinical information available from veterinarian. For an accurate result, It is suggested to apply other method such as PCR for final determination in practice.